Mechanical Follow-the-Leader motion of a hyper-redundant surgical instrument: Proof-of-concept prototype and first tests

One of the most prominent drivers in the development of surgical procedures is the will to reduce their invasiveness, attested by minimally invasive surgery being the gold standards in many surgical procedures and natural orifices transluminal endoscopic surgery gaining acceptance. A logical next step in this pursuit is the introduction of hyper-redundant instruments that can insert themselves along multi-curved paths referred to as Follow-the-Leader motion. In the current state of the art, two different types of Follow-the-Leader instruments can be distinguished. One type of instrument is robotized; the movements of the shaft are controlled from outside the patient by actuators, for example, electric motors, and a controller storing a virtual track of the desired path. The other type of instrument is more mechanical; the movements of the shaft are controlled from inside the patient by a physical track that guides the shaft along the desired path. While in the robotized approach all degrees of freedom of the shaft require an individual actuator, the mechanical approach makes the number of degrees of freedom independent from the number of actuators. A desirable feature as an increasing number of actuators will inevitably drive up costs and increase the footprint of an instrument. Building the physical track inside the body does, however, impede miniaturization of the shaft’s diameter. This article introduces a new fully mechanical approach for Follow-the-Leader motion using a pre-determined physical track that is placed outside the body. This new approach was validated with a prototype called MemoFlex, which supports a Ø5 mm shaft (standard size in minimally invasive surgery) that contains 28-degrees-of-freedom and utilizes a simple steel rod as its physical track. Even though the performance of the MemoFlex leaves room for improvement, especially when following multiple curves, it does validate the proposed concept for Follow-the-Leader motion in three-dimensional space.

[1]  Robert J. Webster,et al.  Toward Active Cannulas: Miniature Snake-Like Surgical Robots , 2006, 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[2]  P. Breedveld,et al.  A new, easily miniaturized steerable endoscope , 2005, IEEE Engineering in Medicine and Biology Magazine.

[3]  Jaebum Son,et al.  A novel semi-automatic snake robot for natural orifice transluminal endoscopic surgery: preclinical tests in animal and human cadaver models (with video) , 2015, Surgical Endoscopy.

[4]  Howie Choset,et al.  Demonstration of transoral surgery in cadaveric specimens with the medrobotics flex system , 2013, The Laryngoscope.

[5]  Pierre E. Dupont,et al.  Design and Control of Concentric-Tube Robots , 2010, IEEE Transactions on Robotics.

[6]  H. Choset,et al.  A highly articulated robotic surgical system for minimally invasive surgery. , 2009, The Annals of thoracic surgery.

[7]  Robert J. Webster,et al.  Can concentric tube robots follow the leader? , 2013, 2013 IEEE International Conference on Robotics and Automation.

[8]  Philip J Swaney,et al.  Forces Applied at the Skull Base during Transnasal Endoscopic Transsphenoidal Pituitary Tumor Excision , 2013, Journal of Neurological Surgery—Part B.

[9]  Gerwin Smit,et al.  The MemoSlide: An explorative study into a novel mechanical follow-the-leader mechanism , 2017, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[10]  Howie Choset,et al.  A transoral highly flexible robot , 2012, The Laryngoscope.

[11]  Jens Kotlarski,et al.  Towards a follow-the-leader control for a binary actuated hyper-redundant manipulator , 2015, 2015 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS).

[12]  D. Caleb Rucker,et al.  A bimanual teleoperated system for endonasal skull base surgery , 2011, 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[13]  P. Cappabianca,et al.  Endoscopic endonasal transsphenoidal surgery. , 2002, Advances and technical standards in neurosurgery.

[14]  Howie Choset,et al.  A Follow-the-Leader Approach to Serpentine Robot Motion Planning , 1999 .

[15]  D. Caleb Rucker,et al.  Concentric Tube Robots: The State of the Art and Future Directions , 2013, ISRR.

[16]  Howie Choset,et al.  Continuum Robots for Medical Applications: A Survey , 2015, IEEE Transactions on Robotics.

[17]  Edoardo Sinibaldi,et al.  The First Interlaced Continuum Robot, Devised to Intrinsically Follow the Leader , 2016, PloS one.

[18]  J. Waye,et al.  Quo Vadis: Another New Colonoscope , 2007, The American Journal of Gastroenterology.

[19]  Maria Neumann,et al.  Considerations for follow-the-leader motion of extensible tendon-driven continuum robots , 2016, 2016 IEEE International Conference on Robotics and Automation (ICRA).

[20]  Dragos Axinte,et al.  Real-time method for tip following navigation of continuum snake arm robots , 2014, Robotics Auton. Syst..

[21]  Jean Anderson Eloy,et al.  Surgical nuances for removal of olfactory groove meningiomas using the endoscopic endonasal transcribriform approach. , 2011, Neurosurgical focus.

[22]  T. Hucl,et al.  Natural orifice transluminal endoscopic surgery , 2011, Endoscopy.

[23]  F. Esposito,et al.  Extended endoscopic endonasal approach to the midline skull base: the evolving role of transsphenoidal surgery. , 2008, Advances and technical standards in neurosurgery.

[24]  Robert J. Webster,et al.  A Telerobotic System for Transnasal Surgery , 2014, IEEE/ASME Transactions on Mechatronics.

[25]  J Dankelman,et al.  Scopes Too Flexible...and Too Stiff , 2010, IEEE Pulse.

[26]  P. Breedveld,et al.  A state of the art review and categorization of multi-branched instruments for NOTES and SILS , 2015, Surgical Endoscopy.

[27]  Robert J. Webster,et al.  Concentric Tube Robots as Steerable Needles: Achieving Follow-the-Leader Deployment , 2015, IEEE Transactions on Robotics.

[28]  Guang-Zhong Yang,et al.  An articulated universal joint based flexible access robot for minimally invasive surgery , 2011, 2011 IEEE International Conference on Robotics and Automation.

[29]  Jessica Burgner-Kahrs,et al.  Toward improving path following motion: Hybrid continuum robot design , 2017, 2017 IEEE International Conference on Robotics and Automation (ICRA).