Evaluation of regression-based 3-D shoulder rhythms.

The movements of the humerus, the clavicle, and the scapula are not completely independent. The coupled pattern of movement of these bones is called the shoulder rhythm. To date, multiple studies have focused on providing regression-based 3-D shoulder rhythms, in which the orientations of the clavicle and the scapula are estimated by the orientation of the humerus. In this study, six existing regression-based shoulder rhythms were evaluated by an independent dataset in terms of their predictability. The datasets include the measured orientations of the humerus, the clavicle, and the scapula of 14 participants over 118 different upper arm postures. The predicted orientations of the clavicle and the scapula were derived from applying those regression-based shoulder rhythms to the humerus orientation. The results indicated that none of those regression-based shoulder rhythms provides consistently more accurate results than the others. For all the joint angles and all the shoulder rhythms, the RMSE are all greater than 5°. Among those shoulder rhythms, the scapula lateral/medial rotation has the strongest correlation between the predicted and the measured angles, while the other thoracoclavicular and thoracoscapular bone orientation angles only showed a weak to moderate correlation. Since the regression-based shoulder rhythm has been adopted for shoulder biomechanical models to estimate shoulder muscle activities and structure loads, there needs to be further investigation on how the predicted error from the shoulder rhythm affects the output of the biomechanical model.

[1]  Bryan Buchholz,et al.  ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion--Part II: shoulder, elbow, wrist and hand. , 2005, Journal of biomechanics.

[2]  L. A. Rozendaal,et al.  Load on the shoulder in low intensity wheelchair propulsion. , 2002, Clinical biomechanics.

[3]  Richard Taylor Interpretation of the Correlation Coefficient: A Basic Review , 1990 .

[4]  Raymond W. McGorry,et al.  A regression-based 3-D shoulder rhythm. , 2014, Journal of biomechanics.

[5]  J. D. de Groot,et al.  A three-dimensional regression model of the shoulder rhythm. , 2001, Clinical biomechanics.

[6]  B Peterson,et al.  Biomechanical model of the human shoulder joint--II. The shoulder rhythm. , 1991, Journal of biomechanics.

[7]  M. Morris,et al.  The reliability of three-dimensional kinematic gait measurements: a systematic review. , 2009, Gait & posture.

[8]  Scott Tashman,et al.  The inaccuracy of surface-measured model-derived tibiofemoral kinematics. , 2012, Journal of biomechanics.

[9]  G R Johnson,et al.  A method for the measurement of three-dimensional scapular movement. , 1993, Clinical biomechanics.

[10]  F. V. D. van der Helm,et al.  Three-dimensional recording and description of motions of the shoulder mechanism. , 1995, Journal of biomechanical engineering.

[11]  Xu Xu,et al.  Transformation between different local coordinate systems of the scapula. , 2012, Journal of biomechanics.

[12]  J. Saunders,et al.  Observations of the Function of the Shoulder Joint , 1996, Clinical orthopaedics and related research.

[13]  K. An,et al.  Monte Carlo simulation of a planar shoulder model , 1997, Medical and Biological Engineering and Computing.

[14]  Don B Chaffin,et al.  Experimental evaluation of a computational shoulder musculoskeletal model. , 2008, Clinical biomechanics.

[15]  A R Karduna,et al.  Dynamic measurements of three-dimensional scapular kinematics: a validation study. , 2001, Journal of biomechanical engineering.

[16]  Scott L. Delp,et al.  A Model of the Upper Extremity for Simulating Musculoskeletal Surgery and Analyzing Neuromuscular Control , 2005, Annals of Biomedical Engineering.

[17]  Mohsen Makhsous Improvements, Validation and Adaptation of a Shoulder Model , 1999 .

[18]  Anthony M J Bull,et al.  Skin-fixed scapula trackers: a comparison of two dynamic methods across a range of calibration positions. , 2011, Journal of biomechanics.

[19]  P Herberts,et al.  Biomechanical model of the human shoulder--I. Elements. , 1987, Journal of biomechanics.

[20]  J. D. de Groot,et al.  Comparison between tripod and skin-fixed recording of scapular motion. , 2007, Journal of biomechanics.

[21]  D Karlsson,et al.  Towards a model for force predictions in the human shoulder. , 1992, Journal of biomechanics.

[22]  A. Cappello,et al.  Soft tissue artefact assessment in humeral axial rotation. , 2004, Gait & posture.

[23]  Clark R Dickerson,et al.  A novel three-dimensional shoulder rhythm definition that includes overhead and axially rotated humeral postures. , 2013, Journal of biomechanics.

[24]  Andrew Merryweather,et al.  A computational study of shoulder muscle forces during pushing tasks , 2013 .

[25]  Don B Chaffin,et al.  A mathematical musculoskeletal shoulder model for proactive ergonomic analysis , 2007, Computer methods in biomechanics and biomedical engineering.

[26]  F.C.T. van der Helm,et al.  A finite element musculoskeletal model of the shoulder mechanism. , 1994 .

[27]  Amir Abbas Zadpoor,et al.  Transformation methods for estimation of subject-specific scapular muscle attachment sites , 2014, Computer methods in biomechanics and biomedical engineering.

[28]  Paolo de Leva,et al.  Joint center longitudinal positions computed from a selected subset of Chandler's data , 1996 .