Validation of the Delft Shoulder and Elbow Model using in-vivo glenohumeral joint contact forces.

The Delft Shoulder and Elbow Model (DSEM), a large-scale musculoskeletal model, is used for the estimation of muscle and joint reaction forces in the shoulder and elbow complex. Although the model has been qualitatively verified using EMG-signals, quantitative validation has until recently not been feasible. The development of an instrumented shoulder endoprosthesis has now made this possible. To this end, motion data, EMG-signals, external forces, and in-vivo glenohumeral joint reaction forces (GH-JRF) were recorded for two patients with an instrumented shoulder hemi-arthroplasty, during dynamic tasks (including abduction and anteflexion) and force tasks with the arm held in a static position. Motions and external forces served as the model inputs to estimate the GH-JRF. In the modeling process, the effect of two different (stress and energy) optimization cost functions and uniform size and mass scaling were evaluated. The model-estimated GH-JRF followed the in-vivo measured force for dynamic tasks up to about 90° arm elevations, but generally underestimates the peak forces up to 31%; whereas a different behavior (ascending measured but descending estimated force) was found for angles above 90°. For the force tasks the model generally overestimated the peak GH-JRF for most directions (on average up to 34%). Applying the energy cost function improved model predictions for the dynamic anteflexion task (up to 9%) and for the force task (on average up to 23%). Scaling also led to improvement of the model predictions during the dynamic tasks (up to 26%), but had a negligible effect (<2%) on the force task results. Although results indicated a reasonable compatibility between model and measured data, adjustments will be necessary to individualize the generic model with the patient-specific characteristics.

[1]  F. V. D. van der Helm A finite element musculoskeletal model of the shoulder mechanism. , 1994, Journal of biomechanics.

[2]  L. A. Rozendaal,et al.  Load on the shoulder in low intensity wheelchair propulsion. , 2002, Clinical biomechanics.

[3]  F C T van der Helm,et al.  A kinematical analysis of the shoulder after arthroplasty during a hair combing task. , 2006, Clinical biomechanics.

[4]  Philippe Favre,et al.  An algorithm for estimation of shoulder muscle forces for clinical use. , 2005, Clinical biomechanics.

[5]  R. Crowninshield,et al.  A physiologically based criterion of muscle force prediction in locomotion. , 1981, Journal of biomechanics.

[6]  Michael Damsgaard,et al.  Analysis of musculoskeletal systems in the AnyBody Modeling System , 2006, Simul. Model. Pract. Theory.

[7]  Paul Suetens,et al.  Personalized MR-based musculoskeletal models compared to rescaled generic models in the presence of increased femoral anteversion: effect on hip moment arm lengths. , 2008, Gait & posture.

[8]  John Rasmussen,et al.  ANALYSIS OF THE MUSCLE AND JOINT FORCES IN THE SHOULDER JOINT USING THE ANYBODY SIMULATION MODEL , 2008 .

[9]  H E Veeger,et al.  The position of the rotation center of the glenohumeral joint. , 2000, Journal of biomechanics.

[10]  F. V. D. van der Helm Analysis of the kinematic and dynamic behavior of the shoulder mechanism. , 1994, Journal of biomechanics.

[11]  F. V. D. van der Helm,et al.  The relationship between two different mechanical cost functions and muscle oxygen consumption. , 2006, Journal of biomechanics.

[12]  R Happee,et al.  The control of shoulder muscles during goal directed movements, an inverse dynamic analysis. , 1992, Journal of biomechanics.

[13]  F.C.T. van der Helm,et al.  A finite element musculoskeletal model of the shoulder mechanism. , 1994 .

[14]  Bryan Buchholz,et al.  ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion--Part II: shoulder, elbow, wrist and hand. , 2005, Journal of biomechanics.

[15]  A Rohlmann,et al.  An instrumented implant for in vivo measurement of contact forces and contact moments in the shoulder joint. , 2009, Medical engineering & physics.

[16]  J. Saunders,et al.  Relation of human electromyogram to muscular tension. , 1952, Electroencephalography and clinical neurophysiology.

[17]  A Rohlmann,et al.  In vivo glenohumeral contact forces--measurements in the first patient 7 months postoperatively. , 2007, Journal of biomechanics.

[18]  Michael Damsgaard,et al.  COMPARISON OF A MUSCULOSKELETAL SHOULDER MODEL WITH IN-VIVO JOINT FORCES , 2007 .

[19]  F C T van der Helm,et al.  Biomechanical analysis of tendon transfers for massive rotator cuff tears. , 2004, Clinical biomechanics.

[20]  G R Johnson,et al.  A model for the prediction of the forces at the glenohumeral joint , 2006, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[21]  Antonius Rohlmann,et al.  IN VIVO SHOULDER JOINT FORCES AT ISOLATED MOTIONS , 2008 .

[22]  C. Spoor,et al.  Measuring muscle and joint geometry parameters of a shoulder for modeling purposes. , 1999, Journal of biomechanics.

[23]  D Karlsson,et al.  Towards a model for force predictions in the human shoulder. , 1992, Journal of biomechanics.

[24]  F C T van der Helm,et al.  Shoulder function: the perfect compromise between mobility and stability. , 2007, Journal of biomechanics.

[25]  Christian Gerber,et al.  Numerical modelling of the shoulder for clinical applications , 2009, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[26]  H J Woltring,et al.  Instantaneous helical axis estimation from 3-D video data in neck kinematics for whiplash diagnostics. , 1994, Journal of biomechanics.

[27]  A. Rohlmann,et al.  In vivo measurement of shoulder joint loads during activities of daily living. , 2009, Journal of biomechanics.

[28]  Alain Farron,et al.  An algorithm to allow humerus translation in the indeterminate problem of shoulder abduction. , 2008, Medical engineering & physics.

[29]  F. V. D. van der Helm,et al.  Effectiveness of tendon transfers for massive rotator cuff tears: a simulation study. , 2004, Clinical biomechanics.

[30]  C.G.M. Meskers,et al.  3D shoulder position measurements using a six-degree-of-freedom electromagnetic tracking device. , 1998, Clinical biomechanics.

[31]  H E J Veeger,et al.  Mechanical Evaluation of the Pronator Teres Rerouting Tendon Transfer , 2004, Journal of hand surgery.

[32]  N Verdonschot,et al.  Frictional heating of total hip implants. Part 1: measurements in patients. , 2001, Journal of biomechanics.

[33]  F. V. D. van der Helm,et al.  Three-dimensional recording and description of motions of the shoulder mechanism. , 1995, Journal of biomechanical engineering.

[34]  A Keys,et al.  Indices of relative weight and obesity. , 1972, Journal of chronic diseases.

[35]  Poppen Nk,et al.  Forces at the glenohumeral joint in abduction. , 1978 .

[36]  Scott L. Delp,et al.  A Model of the Upper Extremity for Simulating Musculoskeletal Surgery and Analyzing Neuromuscular Control , 2005, Annals of Biomedical Engineering.

[37]  P M Rozing,et al.  Glenohumeral stability in simulated rotator cuff tears. , 2009, Journal of biomechanics.

[38]  K. An,et al.  Parameters for modeling the upper extremity. , 1997, Journal of biomechanics.

[39]  Frans C. T. van der Helm,et al.  Musculoskeletal Systems with Intrinsic and Proprioceptive Feedback , 2000 .

[40]  N. Poppen,et al.  Forces at the glenohumeral joint in abduction. , 1978, Clinical orthopaedics and related research.