GPR-Based Water Leak Models in Water Distribution Systems

This paper addresses the problem of leakage in water distribution systems through the use of ground penetrating radar (GPR) as a nondestructive method. Laboratory tests are performed to extract features of water leakage from the obtained GPR images. Moreover, a test in a real-world urban system under real conditions is performed. Feature extraction is performed by interpreting GPR images with the support of a pre-processing methodology based on an appropriate combination of statistical methods and multi-agent systems. The results of these tests are presented, interpreted, analyzed and discussed in this paper.

[1]  Dongling Qiu,et al.  A case study to detect the leakage of underground pressureless cement sewage water pipe using GPR, electrical, and chemical data. , 2002, Environmental science & technology.

[2]  Michael Burrow,et al.  Condition assessment of the buried utility service infrastructure , 2012 .

[3]  Young Sik Kim,et al.  The laboratory scaled-down model of a ground-penetrating radar for leak detection of water pipes , 2007 .

[4]  Joaquín Izquierdo,et al.  Location of buried plastic pipes using multi-agent support based on GPR images , 2011 .

[5]  F. Vallianatos,et al.  Detection of leaks in buried plastic water distribution pipes in urban places - a case study , 2003, Proceedings of the 2nd International Workshop onAdvanced Ground Penetrating Radar, 2003..

[6]  Francesco Soldovieri,et al.  BISTATIC TOMOGRAPHIC GPR IMAGING FOR INCIPIENT PIPELINE LEAKAGE EVALUATION , 2010 .

[7]  Osama Hunaidi,et al.  GROUND-PENETRATING RADAR FOR DETECTION OF LEAKS IN BURIED PLASTIC WATER DISTRIBUTION PIPES , 1998 .

[8]  Yoav Shoham,et al.  Multiagent Systems - Algorithmic, Game-Theoretic, and Logical Foundations , 2009 .

[9]  Alaa Ezzat Hasan THE USE OF GROUND PENETRATING RADAR WITH A FREQUENCY 1GHZ TO DETECT WATER LEAKS FROM PIPELINES , 2012 .

[10]  Angelos Amditis,et al.  Detection of water leaks in supply pipes using continuous wave sensor operating at 2.45 GHz , 2010 .

[11]  Idel Montalvo,et al.  Water supply system component evaluation from GPR radargrams using a multi-agent approach , 2013, Math. Comput. Model..

[12]  Mario Tavera Aplicación del georadar para la mejora del rendimiento de una red hídrica , 2011 .

[13]  Jean Ponce,et al.  Automatic alignment of paintings and photographs depicting a 3D scene , 2011, 2011 IEEE International Conference on Computer Vision Workshops (ICCV Workshops).

[14]  Sevket Demirci,et al.  Ground penetrating radar imaging of water leaks from buried pipes based on back-projection method , 2012 .

[15]  Matthew Charlton,et al.  Efficient detection of mains water leaks using ground-penetrating radar (GPR) , 2001, Optics + Photonics.

[16]  Joaquín Izquierdo,et al.  Water Supply Clusters by Multi-Agent Based Approach , 2011 .

[17]  Jay N. Meegoda,et al.  Acoustic Emission Leak Detection on a Metal Pipeline Buried in Sandy Soil , 2013 .