Experimental validation of the pseudo-rigid-body model of the MRI-actuated catheter

An MRI-actuated catheter is a novel robotic catheter system that utilizes the MRI for both remote steering and visualization for catheter ablation of atrial fibrillation. Planning and control of the catheter requires a sufficiently fast yet accurate model of the catheter. The pseudo-rigid-body (PRB) model offers a reasonable trade-off between speed and accuracy by approximating the continuum catheter as rigid links connected by flexible joints, thus reducing the infinite degrees of freedom of the continuum mechanism to a finite one. In this paper, a PRB model of the MRI-actuated catheter is validated experimentally by comparing the deflections of the PRB model with the deflections of the catheter prototype.

[1]  Du Q. Huynh,et al.  Metrics for 3D Rotations: Comparison and Analysis , 2009, Journal of Mathematical Imaging and Vision.

[2]  Gregory S. Chirikjian,et al.  The kinematics of hyper-redundant robot locomotion , 1995, IEEE Trans. Robotics Autom..

[3]  J L Duerk,et al.  Control of intravascular catheters using an array of active steering coils. , 2011, Medical physics.

[4]  W. Marsden I and J , 2012 .

[5]  Hai-Jun Su,et al.  A parameter optimization framework for determining the pseudo-rigid-body model of cantilever-beams , 2015 .

[6]  Rajnikant V. Patel,et al.  A pseudo-rigid-body 3R model for a steerable ablation catheter , 2013, 2013 IEEE International Conference on Robotics and Automation.

[7]  Howie Choset,et al.  Continuum Robots for Medical Applications: A Survey , 2015, IEEE Transactions on Robotics.

[8]  Hai-Jun Su,et al.  A Pseudorigid-Body 3R Model for Determining Large Deflection of Cantilever Beams Subject to Tip Loads , 2009 .

[9]  Pierre E. Dupont,et al.  Design and Control of Concentric-Tube Robots , 2010, IEEE Transactions on Robotics.

[10]  David Dugdale Essentials of electromagnetism , 1993 .

[11]  Murat Cenk Cavusoglu,et al.  Catadioptric stereo tracking for three dimensional shape measurement of MRI guided catheters , 2016, 2016 IEEE International Conference on Robotics and Automation (ICRA).

[12]  David Keane,et al.  2012 HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design. , 2012, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[13]  Larry L. Howell,et al.  Handbook of Compliant Mechanisms: Howell/Handbook , 2013 .

[14]  John Kenneth Salisbury,et al.  Mechanics Modeling of Tendon-Driven Continuum Manipulators , 2008, IEEE Transactions on Robotics.

[15]  Guimin Chen,et al.  Finding the optimal characteristic parameters for 3R pseudo-rigid-body model using an improved particle swarm optimizer , 2011 .

[16]  L. Tsai,et al.  Modeling of Flexural Beams Subjected to Arbitrary End Loads , 2002 .

[17]  Robert J. Webster,et al.  Design and Kinematic Modeling of Constant Curvature Continuum Robots: A Review , 2010, Int. J. Robotics Res..

[18]  Sridhar Kota,et al.  Synthesis of Planar, Compliant Four-Bar Mechanisms for Compliant-Segment Motion Generation four-bar mechanisms treated in previous works consisted of at least one rigid , 2001 .

[19]  Wolters Kluwer,et al.  Hrs/ehra/ecas Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: Recommendations for Patient Selection, Procedural Techniques, Patient Management and Follow-up, Definitions, Endpoints, and Research Trial Design: a Report of the Heart Rhythm Society (hrs) Task Force , 2022 .

[20]  A. Midha,et al.  Parametric Deflection Approximations for End-Loaded, Large-Deflection Beams in Compliant Mechanisms , 1995 .

[21]  Murat Cenk Cavusoglu,et al.  Pseudo-rigid-body model and kinematic analysis of MRI-actuated catheters , 2015, 2015 IEEE International Conference on Robotics and Automation (ICRA).

[22]  Anupam Saxena,et al.  A Simple and Accurate Method for Determining Large Deflections in Compliant Mechanisms Subjected to End Forces and Moments , 1998 .

[23]  Mark A. Griswold,et al.  Modeling and Validation of the Three-Dimensional Deflection of an MRI-Compatible Magnetically Actuated Steerable Catheter , 2016, IEEE Transactions on Biomedical Engineering.

[24]  Larry L. Howell,et al.  Handbook of compliant mechanisms , 2013 .

[25]  R L Arenson,et al.  Remote control of catheter tip deflection: An opportunity for interventional MRI , 2002, Magnetic resonance in medicine.