Soft Robotic Haptic Interface with Variable Stiffness for Rehabilitation of Neurologically Impaired Hand Function

The human hand comprises complex sensorimotor functions that can be impaired by neurological diseases and traumatic injuries. Effective rehabilitation can bring the impaired hand back to a functional state because of the plasticity of the central nervous system to relearn and remodel the lost synapses in the brain. Current rehabilitation therapies focus on strengthening motor skills, such as grasping, employ multiple objects of varying stiffness so that affected persons can experience a wide range of strength training. These devices have limited range of stiffness due to the rigid mechanisms employed in their variable stiffness actuators. This paper presents a novel soft robotic haptic device for neuromuscular rehabilitation of the hand, which is designed to offer adjustable stiffness and can be utilized in both clinical and home settings. The device eliminates the need for multiple objects by employing a pneumatic soft structure made with highly compliant materials that act as the actuator of the haptic interface. It is made with interchangeable sleeves that can be customized to include materials of varying stiffness to increase the upper limit of the stiffness range. The device is fabricated using existing 3-D printing technologies, and polymer molding and casting techniques thus keeping the cost low and throughput high. The haptic interface is linked to either an open-loop system that allows for an increased pressure during usage or closed-loop system that provides pressure regulation in accordance to the stiffness the user specifies. Preliminary evaluation is performed to characterize the effective controllable region of variance in stiffness. It was found that the region of controllable stiffness was between points 3 and 7, where the stiffness appeared to plateau with each increase in pressure. The two control systems are tested to derive relationships between internal pressure, grasping force exertion on the surface, and displacement using multiple probing points on the haptic device. Additional quantitative evaluation is performed with study participants and juxtaposed to a qualitative analysis to ensure adequate perception in compliance variance. The qualitative evaluation showed that greater than 60% of the trials resulted in the correct perception of stiffness in the haptic device.

[1]  J. Kleim,et al.  Neural Plasticity: The Biological Substrate For Neurorehabilitation , 2010, PM & R : the journal of injury, function, and rehabilitation.

[2]  Daniel B Hier,et al.  The Stroke Data Bank: design, methods, and baseline characteristics. , 1988, Stroke.

[3]  Robert J. Wood,et al.  Modeling of Soft Fiber-Reinforced Bending Actuators , 2015, IEEE Transactions on Robotics.

[4]  Hong Kai Yap,et al.  Design and characterization of low-cost fabric-based flat pneumatic actuators for soft assistive glove application , 2017, 2017 International Conference on Rehabilitation Robotics (ICORR).

[5]  H. Ellis stroke , 1997, The Lancet.

[6]  J. Holmes,et al.  Lifetime cost of stroke in the United States. , 1996, Stroke.

[7]  Astrid M. L. Kappers,et al.  Cues for Haptic Perception of Compliance , 2009, IEEE Transactions on Haptics.

[8]  Allison M. Okamura,et al.  Perception of a Haptic Jamming display: Just noticeable differences in stiffness and geometry , 2014, 2014 IEEE Haptics Symposium (HAPTICS).

[9]  Hilla Peretz,et al.  The , 1966 .

[10]  Matteo Malosio,et al.  An affordable, adaptable, and hybrid assistive device for upper-limb neurorehabilitation , 2016, Journal of rehabilitation and assistive technologies engineering.

[11]  MajidiCarmel,et al.  Soft Robotics: A Perspective—Current Trends and Prospects for the Future , 2014 .

[12]  Hossein Mousavi Hondori,et al.  Haptic Augmented Reality to monitor human arm's stiffness in rehabilitation , 2012, 2012 IEEE-EMBS Conference on Biomedical Engineering and Sciences.

[13]  T. Olsen,et al.  Recovery of walking function in stroke patients: the Copenhagen Stroke Study. , 1995, Archives of physical medicine and rehabilitation.

[14]  Kyler M. Godwin,et al.  Cost Associated with Stroke: Outpatient Rehabilitative Services and Medication , 2011, Topics in stroke rehabilitation.

[15]  Thomas J. Armstrong,et al.  Investigation of Grip Force, Normal Force, Contact Area, Hand Size, and Handle Size for Cylindrical Handles , 2008, Hum. Factors.

[16]  H.I. Krebs,et al.  Whole-Arm Rehabilitation Following Stroke: Hand Module , 2006, The First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, 2006. BioRob 2006..

[17]  Stephen A. Morin,et al.  Soft Robotics: Review of Fluid‐Driven Intrinsically Soft Devices; Manufacturing, Sensing, Control, and Applications in Human‐Robot Interaction   , 2017 .

[18]  V. Caron,et al.  United states. , 2018, Nursing standard (Royal College of Nursing (Great Britain) : 1987).

[19]  C. Majidi Soft Robotics: A Perspective—Current Trends and Prospects for the Future , 2014 .

[20]  T. Olsen,et al.  Recovery of upper extremity function in stroke patients: the Copenhagen Stroke Study. , 1994, Archives of physical medicine and rehabilitation.

[21]  C. Winstein,et al.  A randomized controlled comparison of upper-extremity rehabilitation strategies in acute stroke: A pilot study of immediate and long-term outcomes. , 2004, Archives of physical medicine and rehabilitation.

[22]  C. Wolfe,et al.  A long-term follow-up of stroke patients. , 1997, Stroke.

[23]  Pamela W. Duncan,et al.  Similar Motor Recovery of Upper and Lower Extremities After Stroke , 1994, Stroke.

[24]  Allison M. Okamura,et al.  Haptic jamming: A deformable geometry, variable stiffness tactile display using pneumatics and particle jamming , 2013, 2013 World Haptics Conference (WHC).

[25]  J. Kleim,et al.  Principles of experience-dependent neural plasticity: implications for rehabilitation after brain damage. , 2008, Journal of speech, language, and hearing research : JSLHR.

[26]  Matteo Malosio,et al.  Analysis and synthesis of LinWWC-VSA, a Variable Stiffness Actuator for linear motion , 2017 .

[27]  Oliver Brock,et al.  A compliant hand based on a novel pneumatic actuator , 2013, 2013 IEEE International Conference on Robotics and Automation.

[28]  Etienne Burdet,et al.  Elasticity improves handgrip performance and user experience during visuomotor control , 2017, Royal Society Open Science.

[29]  Robert J. Wood,et al.  Soft robotic glove for combined assistance and at-home rehabilitation , 2015, Robotics Auton. Syst..

[30]  D.B. Popovic,et al.  Hybrid Assistive Systems for Rehabilitation: Lessons Learned from Functional Electrical Therapy in Hemiplegics , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[31]  Etienne Burdet,et al.  Rehabilitation of grasping and forearm pronation/supination with the Haptic Knob , 2009, 2009 IEEE International Conference on Rehabilitation Robotics.

[32]  E. Burdet,et al.  Robot-assisted rehabilitation of hand function. , 2010, Current opinion in neurology.

[33]  W. B. Tiest Tactual perception of material properties , 2010, Vision Research.

[34]  I. Hunter,et al.  A perceptual analysis of stiffness , 2004, Experimental Brain Research.

[35]  Sridhar Kota,et al.  Design and Modeling of Generalized Fiber-Reinforced Pneumatic Soft Actuators , 2015, IEEE Transactions on Robotics.

[36]  Peter Langhorne,et al.  Occupational therapy for patients with problems in personal activities of daily living after stroke: systematic review of randomised trials , 2007, BMJ : British Medical Journal.