Teleimpedance Control: Overview and Application

In previous chapters, human hand and arm kinematics have been analyzed through a synergstic approach and the underlying concepts were used to design robotic systems and devise simplified control algorithms. On the other hand, it is well-known that synergies can be studied also at a muscular level as a coordinated activation of multiple muscles acting as a single unit to generate different movements. As a result, muscular activations, quantified through Electromyography (EMG) signals can be then processed and used as direct inputs to external devices with a large number of DOFs. In this chapter, we present a minimalistic approach based on tele-impedance control, where EMGs from only one pair of antagonistic muscle pair are used to map the users postural and stiffness references to the synergy-driven anthropomorphic robotic hand, described in Chap. 7. In this direction, we first provide an overview of the teleimpedance control concept which forms the basis for the development of the hand controller. Eventually, experimental results evaluate the effectiveness of the teleimpedance control concept in execution of the tasks which require significant dynamics variation or are executed in remote environments with dynamic uncertainties.

[1]  Antonio Bicchi,et al.  Modelling natural and artificial hands with synergies , 2011, Philosophical Transactions of the Royal Society B: Biological Sciences.

[2]  Patrick van der Smagt,et al.  Surface EMG in advanced hand prosthetics , 2008, Biological Cybernetics.

[3]  Bruce A. Francis,et al.  Bilateral controller for teleoperators with time delay via μ-synthesis , 1995, IEEE Trans. Robotics Autom..

[4]  R. Trumbower,et al.  Use of Self-Selected Postures to Regulate Multi-Joint Stiffness During Unconstrained Tasks , 2009, PloS one.

[5]  T. Milner Contribution of geometry and joint stiffness to mechanical stability of the human arm , 2002, Experimental Brain Research.

[6]  E. Bizzi,et al.  Neural, mechanical, and geometric factors subserving arm posture in humans , 1985, The Journal of neuroscience : the official journal of the Society for Neuroscience.

[7]  Peter J. Beek,et al.  Can co-activation reduce kinematic variability? A simulation study , 2005, Biological Cybernetics.

[8]  Blake Hannaford,et al.  Experimental and simulation studies of hard contact in force reflecting teleoperation , 1988, Proceedings. 1988 IEEE International Conference on Robotics and Automation.

[9]  Nikos G. Tsagarakis,et al.  Human-inspired balancing assistance: Application to a knee exoskeleton , 2013 .

[10]  Nikolaos G. Tsagarakis,et al.  Tele-impedance based assistive control for a compliant knee exoskeleton , 2015, Robotics Auton. Syst..

[11]  G. Genta Vibration of structures and machines , 1993 .

[12]  Paul L Gribble,et al.  Role of cocontraction in arm movement accuracy. , 2003, Journal of neurophysiology.

[13]  Nikolaos G. Tsagarakis,et al.  TeleImpedance: Exploring the role of common-mode and configuration-dependant stiffness , 2012, 2012 12th IEEE-RAS International Conference on Humanoid Robots (Humanoids 2012).

[14]  Alin Albu-Schäffer,et al.  The DLR lightweight robot: design and control concepts for robots in human environments , 2007, Ind. Robot.

[15]  K. Akazawa,et al.  Modulation of reflex EMG and stiffness in response to stretch of human finger muscle. , 1983, Journal of neurophysiology.

[16]  Patrick van der Smagt,et al.  EMG-based teleoperation and manipulation with the DLR LWR-III , 2011, 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[17]  P. Crago,et al.  Multijoint dynamics and postural stability of the human arm , 2004, Experimental Brain Research.

[18]  Nikolaos G. Tsagarakis,et al.  Antagonistic and series elastic actuators: a comparative analysis on the energy consumption , 2009, 2009 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[19]  Clément Gosselin,et al.  Underactuated Robotic Hands , 2008, Springer Tracts in Advanced Robotics.

[20]  Antonio Bicchi,et al.  Design and Control of a Variable Stiffness Actuator for Safe and Fast Physical Human/Robot Interaction , 2005, Proceedings of the 2005 IEEE International Conference on Robotics and Automation.

[21]  Manuel G. Catalano,et al.  A synergy-driven approach to a myoelectric hand , 2013, 2013 IEEE 13th International Conference on Rehabilitation Robotics (ICORR).

[22]  Thomas B. Sheridan,et al.  Space teleoperation through time delay: review and prognosis , 1993, IEEE Trans. Robotics Autom..

[23]  Wei-Der Chang,et al.  A feedforward neural network with function shape autotuning , 1996, Neural Networks.

[24]  Walter Herzog,et al.  Model-based estimation of muscle forces exerted during movements. , 2007, Clinical biomechanics.

[25]  T. Milner,et al.  Inability to activate muscles maximally during cocontraction and the effect on joint stiffness , 2004, Experimental Brain Research.

[26]  Claudio Melchiorri,et al.  Force reflecting telemanipulators with time-delay: stability analysis and control design , 1998, IEEE Trans. Robotics Autom..

[27]  M. Kawato,et al.  Adaptation to Stable and Unstable Dynamics Achieved By Combined Impedance Control and Inverse Dynamics Model , 2003 .

[28]  Antonio Bicchi,et al.  Fast and "soft-arm" tactics [robot arm design] , 2004, IEEE Robotics & Automation Magazine.

[29]  H. Gomi,et al.  Multijoint muscle regulation mechanisms examined by measured human arm stiffness and EMG signals. , 1999, Journal of neurophysiology.

[30]  Nikolaos G. Tsagarakis,et al.  Tele-Impedance: Preliminary results on measuring and replicating human arm impedance in tele operated robots , 2011, 2011 IEEE International Conference on Robotics and Biomimetics.

[31]  David J. Ostry,et al.  Compensation for loads during arm movements using equilibrium-point control , 2000, Experimental Brain Research.

[32]  Tsuneo Yoshikawa,et al.  Ground-space bilateral teleoperation of ETS-VII robot arm by direct bilateral coupling under 7-s time delay condition , 2004, IEEE Transactions on Robotics and Automation.

[33]  G. Schreiber,et al.  The Fast Research Interface for the KUKA Lightweight Robot , 2022 .

[34]  Nikolaos G. Tsagarakis,et al.  Exploring Teleimpedance and Tactile Feedback for Intuitive Control of the Pisa/IIT SoftHand , 2014, IEEE Transactions on Haptics.

[35]  T. Milner,et al.  Wrist muscle activation patterns and stiffness associated with stable and unstable mechanical loads , 2004, Experimental Brain Research.

[36]  B. Nigg,et al.  Muscle activity reduces soft-tissue resonance at heel-strike during walking. , 2003, Journal of biomechanics.

[37]  D. Lloyd,et al.  An EMG-driven musculoskeletal model to estimate muscle forces and knee joint moments in vivo. , 2003, Journal of biomechanics.

[38]  Nikolaos G. Tsagarakis,et al.  Tele-impedance: Teleoperation with impedance regulation using a body–machine interface , 2012, Int. J. Robotics Res..

[39]  Toshio Tsuji,et al.  A human-assisting manipulator teleoperated by EMG signals and arm motions , 2003, IEEE Trans. Robotics Autom..

[40]  Alin Albu-Schäffer,et al.  Cartesian impedance control techniques for torque controlled light-weight robots , 2002, Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292).

[41]  H. Gomi,et al.  Task-Dependent Viscoelasticity of Human Multijoint Arm and Its Spatial Characteristics for Interaction with Environments , 1998, The Journal of Neuroscience.

[42]  Alin Albu-Schäffer,et al.  Soft robotics: what Cartesian stiffness can obtain with passively compliant, uncoupled joints? , 2004, 2004 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (IEEE Cat. No.04CH37566).

[43]  Manuel G. Catalano,et al.  Adaptive synergies for the design and control of the Pisa/IIT SoftHand , 2014, Int. J. Robotics Res..